The top-hung window is manufactured in high quality natural pine with the option of white-painted or lacquered pine internal finish (GPL) or white polyurethane internal finish (GPU). It is suitable for installation into roof pitches between 15° and 55°. For installations between 55° and 75° special springs will be required. Not advised for high level (out of reach) installation. The bottom edge of the window should be placed approx. 0.90 – 1.20m above the floor for ease of opertion.
Ventilation bar with dust and insect filter – Allows fresh air to enter the room while the window is securely closed Sash rotates 180° from inside – Allows easy and convenient cleaning Barrel bolt – Allows the window to be locked in to position at 180° for secure cleaning of the exterior pane internally
The sash which is top-hung is opened and closed using the bottom handle and can remain open in any position up to 45o.
Glazing unit Description (--34) glazingOnly available for roof window type GPU Double glazed, laminated opaque inner pane, toughened outer pane. (--50) glazing Double glazed, toughened outer pane. (--60) glazing Double glazed, laminated inner pane, toughened outer pane with easy-to-clean coating, enhanced noise reduction. (--62) glazing Triple glazed, laminated inner pane, toughened outer pane with easy-to-clean and anti-dew coating. Provides enhanced U-value and noise reduction. (--66) glazing Triple glazed, laminated inner, toughened outer pane with easy-to-clean, anti-dew coating and enhanced noise reduction. (--68) glazing Triple glazed, laminated inner, toughened outer pane with easy-to-clean, anti-dew coating and enhanced noise reduction. (--70) glazing Double glazed, laminated inner pane, toughened outer pane.
The pane should be cleaned with a soft, clean, lint-free cloth or non-abrasive sponge. The rest of the window can be cleaned with ordinary household cleaners. The filter can be removed and either washed or replaced.
10 year VELUX guarantee on windows and flashing kits. 3 year guarantee on blinds, shutters, awnings and electrics.
White-painted finishHigh-quality pine wood with water-based long-lasting white paint with discrete wood grain. Perfect for almost all rooms.
White maintenance-free finishStrong core of thermo-modified wood with a seamless waterresistant polyurethene coating. Perfect for high-moisture rooms and out-of-reach solutions.
Natural pine finishHigh-quality pine wood with matte water-based transparent lacquer and visible wood grain. Fits wooden ceilings and wall.
NCS standard colour (Grey): S 7500-N nearest RAL standard colour: 7043. Also available: titanium zinc, copper or coloured aluminium.
Flashings Installation products Linings Single installation (ED_) Twin installation (EB_) Combi installation (EK_) Insulation Collar (BDX) Underfelt Collar (BFX) includes transverse drainage gutter Vapour Barrier (BBX) Linings up to 30 cm roof thickness (LSB) Linings up to 40 cm roof thickness (LSC) Linings up to 50 cm roof thickness (LSD)
Interior sunscreening Awning and shutters Accessories Blackout blind - Manual (DKL) Roller blind - Manual (RFL) Roller blind - Manual (RHL) Roman blind - Manual (FHB) Blackout energy blind - Manual (FHC) Flying pleated blind - Manual (FHL) Venetian blind - Manual (PAL) Duo blackout blind - Manual (DFD) Awning blind - Manual (MHL) Roller shutter - Manual (SHL) Insect screen - Manual (ZIL)
Size Window Options Exterior Frame W x H Visible Glass e x f Lining Rebate k x l CK04 GPL, GPU 550 x 978 371 x 783 495 x 919 CK06 GPL, GPU 550 x 1178 371 x 983 495 x 1119 FK06 GPL, GPU 660 x 1178 481 x 983 605 x 1119 FK08 GPL, GPU 660 x 1398 481 x 1183 605 x 1339 MK04 GPL, GPU 780 x 978 601 x 783 725 x 919 MK06 GPL, GPU 780 x 1178 601 x 983 725 x 1119 MK08 GPL, GPU 780 x 1398 601 x 1203 725 x 1339 MK10 GPL, GPU 780 x 1600 601 x 1405 725 x 1541 PK04 GPL 942 x 978 763 x 783 887 x 919 PK06 GPL, GPU 942 x 1178 763 x 983 887 x 1119 PK08 GPL, GPU 942 x 1398 763 x 1203 887 x 1319 PK10 GPL, GPU 942 x 1600 763 x 1405 887 x 1541 SK06 GPL, GPU 1140 x 1178 961 x 983 1085 x 1119 SK08 GPL, GPU 1140 x 1398 961 x 1203 1085 x 1339 SK10 GPL, GPU 1140 x 1600 961 x 1203 1085 x 1119 UK04 GPL 1340 x 978 1161 x 783 1285 x 919 UK08 GPL, GPU 1340 x 1398 1161 x 1203 1285 x 1339
Size Ventilation flap – free area [10^3mm²]* Ventilation flap – equivalent area [10^3mm²]* 2 layer/3 layer pane Ventilation – open window manual [m²]* Effective daylight area [m²] CK04 2.8 2.6/2.0 0.39 0.29 CK06 2.8 2.6/2.0 0.48 0.37 FK06 3.7 3.1/2.2 0.60 0.47 FK08 3.7 3.1/2.2 0.72 0.58 MK04 4.5 3.7/2.5 0.58 0.47 MK06 4.5 3.7/2.5 0.72 0.59 MK08 4.5 3.7/2.5 0.87 0.72 MK10 4.5 3.7/2.5 1.01 0.85 PK04 6.1 4.6/2.9 0.72 0.60 PK06 6.1 4.6/2.9 0.89 0.75 PK08 6.1 4.6/2.9 1.08 0.92 PK10 6.1 4.6/2.9 1.25 1.07 SK06 7.2 5.6/3.5 1.09 0.95 SK08 7.2 5.6/3.5 1.32 1.16 SK10 7.2 5.6/3.5 1.54 1.35 UK04 10.6 6.6/4.1 1.05 0.91 UK08 10.6 6.6/4.1 1.58 1.40 *Measured to EN 13141-1
Pane variant --34 --50 --60 GPL --62 GPU --62 Thermal transmittance, Uw [W/m2K] 1.3 1.3 1.3 0.83 0.85 Thermal transmittance, Ug [W/m2K] 1.0 1.0 1.0 0.5 0.5 Sound insulation, Rw [dB] 35 32 37 42 42 Air permeability Class 4 Class 4 Class 4 Class 4 Class 4 Light transmittance, Tv 0.51 0.69 0.62 0.70 0.70 Total solar energy transmittance, g 0.46 0.46 0.30 0.52 0.52 Pane variant --66 --68 --70 EN/ISO Standard Thermal transmittance, Uw [W/m2K] 1.0 1.1 1.3 EN ISO 12567-2 Thermal transmittance, Ug [W/m2K] 0.5 0.5 1.0 EN 673 Sound insulation, Rw [dB] 37 35 35 EN ISO 10140-2 Air permeability Class 4 Class 4 Class 4 EN 1026 Light transmittance, Tv 0.71 0.72 0.68 EN 410 Total solar energy transmittance, g 0.51 0.52 0.46 EN 410